FLOWSIC100 Process
FLOWSIC100 Process Reliable and precise volume flow measurement in processes
Sertech001@gmail.com
FLOWSIC100 Process Reliable and precise volume flow measurement in processes
With the FLOWSIC100 Process gas flow measurement devices, measurements can be taken at pressures up to 16 bar – even in zone 2 explosive environments. The sender/receiver units are available as hermetically sealed designs made of stainless steel or titanium. The standard system contains an MCU control unit and 2 sender/receiver units or a single measuring probe. The MCU is used for signal input and output and to calculate reference values (standardization) or mass flow. It also serves as a user-friendly LCD interface.
Corrosion-resistant transducer made of stainless steel or titanium
Up to 16 bar process pressure
Explosion-protected design for applications in zone 2 (ATEX) available
Hermetically sealed ultrasonic transducer
Measurements practically free of pressure loss and without influencing the process
Automated operational check with zero and reference point test
Measured values | Gas velocity, Mass flow rate, volumetric flow a. c., volumetric flow s. c., sound velocity, gas temperature | ||||||||||
Measurement principle | Ultrasonic transit time difference measurement | ||||||||||
Hazardous area | 3G | ||||||||||
Gas temperature | –40 °C ... +260 °C | ||||||||||
Operating pressure | –0.5 bar ... 16 bar Depending on device version | ||||||||||
Nominal pipe size | 0.15 m ... 1.7 m Depending on device version | ||||||||||
Enclosure rating | IP65 | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Diagnostics functions | Automatic check cycle for zero and span point Extended device diagnosis via SOPAS ET software |