FLOWSIC100 Flare
FLOWSIC100 Flare Reliable gas flow measurement in flare gas applications
Sertech001@gmail.com
FLOWSIC100 Flare Reliable gas flow measurement in flare gas applications
The FLOWSIC100 Flare product family is designed for flare gas and steam flow measurements. The product family is characterized by a unique flow-optimized sensor design. This innovative design minimizes flow-generated noise and signal drift when gas velocities are particularly high. Modern signal processing and high-efficiency transducers enable high time resolution for signals and thus deliver accurate measurements, even at extremely low gas flow rates.
The standard system configuration includes two sender/receiver units or one measuring probe and the MCUP control unit. The MCUP unit is used to input and output signals; to calculate reference values (normalization), molecular weight and mass flow; to record gas volumes; and to provide user-friendly control via the LCD display.
High-resolution measurement and short response time
Innovative sensor design for very high gas velocities and gas temperatures up to 280 °C
Optimal signal transmission even under atmospheric pressure
Detached installation of the control unit up to 1,000 m away
Single and multi-path configuration, opt. Probe version
Zero point test in the field according to factory standard
Control cycle for automatic self-diagnosis / signal optimization
Measured values | Gas velocity, gas temperature, gas volume and mass, Mass flow rate, molecular weight, volumetric flow a. c., volumetric flow s. c., sound velocity | ||||||||||
Measurement principle | Ultrasonic transit time difference measurement | ||||||||||
Hazardous area | 1G 2G 3G Class I Division 1 Class I Division 2 Ga Gb Gc | ||||||||||
Measuring ranges | Measuring ranges depend on nominal pipe size and gas composition | ||||||||||
Gas temperature | Standard: –70 °C ... +180 °C High-temperature Zone 1: –70 °C ... +280 °C High-temperature Zone 2: –70 °C ... +260 °C Low temperature: –196 °C ... +100 °C | ||||||||||
Operating pressure | –0.5 bar (g) ... 16 bar (g) FLOWSIC100 EX-S 90°: –0.5 bar (g) ... 19 bar (g) | ||||||||||
Nominal pipe size | 4 ″ ... 72 ″ Depending on gas composition and device version | ||||||||||
Enclosure rating | FLSE100 sender/receiver unit (ATEX zone 1): IP65, IP67 FLSE100 sender/receiver unit (ATEX zone 2): IP65 FLSE100 sender/receiver unit (CSA class I): depending on device version MCUP control unit: IP66 MCUP control unit (19-inch version): IP20 MCUP control unit (Ex zone 1): IP66 MCUP control unit (Ex zone 2/Division 2): housing type 4, IP66 | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
|